[bt_section layout=”boxed” top_spaced=”topSemiSpaced” bottom_spaced=”bottomSemiSpaced” skin=”inherit” full_screen=”no” vertical_align=”inherit” divider=”no” back_image=”” back_color=”” back_overlay=”” back_video=”” video_settings=”” back_video_mp4=”” back_video_ogg=”” back_video_webm=”” parallax=”” parallax_offset=”” animation=”” animation_back=”” animation_impress=”” el_id=”” el_class=”” el_style=””][bt_row][bt_column width=”1/3″ align=”left” vertical_align=”inherit” border=”no_border” cell_padding=”default” animation=”animate animate-fadein” text_indent=”no_text_indent” highlight=”no_highlight” background_color=”” transparent=”” inner_background_color=”” background_image=”” el_class=”” el_style=””][bt_image image=”3590″ caption_text=”” caption_title=”” show_titles=”no” size=”full” shape=”square” url=”” target=”_self” el_class=”” el_style=”” hover_type=”btDefaultHoverType”][/bt_image][bt_hr top_spaced=”topSemiSpaced” bottom_spaced=”not-spaced” transparent_border=”noBorder” el_class=”” el_style=””][/bt_hr][/bt_column][bt_column width=”2/3″ align=”left” vertical_align=”inherit” border=”no_border” cell_padding=”default” animation=”animate animate-fadein” highlight=”no_highlight” background_color=”” transparent=”” inner_background_color=”” background_image=”” el_class=”” el_style=””][bt_header superheadline=”” headline=”Description” headline_size=”small” dash=”bottom” subheadline=”” el_class=”” el_style=”” headline_style=”regular”][/bt_header][bt_hr top_spaced=”not-spaced” bottom_spaced=”bottomSmallSpaced” transparent_border=”noBorder” el_class=”” el_style=””][/bt_hr][bt_text]

TS21I-IR-HC gas detector is suitable for all Hydrocarbon gases. Application area of this detector is Refineries and Petrochemical Plants, Oil and Gas , LPG station, Chemical and Pharma Industries, Fertilizer and Power plants, Gas Boiler, and Spray-Paints etc where gas leakage is possible. It reads the gas concentration in Air and transmits to a detection panel over digital bus as well as it shows LEL level on display. IR type of gas sensor is used in this de-tector. This sensor provides good reproducibility, good performance against changes in atmospheric temperature and humidity. It has long life-span and easy operation. Detector have provision to set Two alarm levels of warnings (High & Low).

PFC Relay output is provided and this output can be connected to the con-ventional Gas Detection Panel OR SCADA system.

For BMS connectivity detector have provide RS485 output. Infrared Sensor is used in this model which does not required calibration frequently. Additionally 4-20mA and Selectable 0-5 V & 0-10V Analog output could be also available. Enclosure used is suitable for Zone 1 & Zone 2 hazardous areas.

Note : Enclosure depicted above is indicative. Specs subject to change with-out notice.

[/bt_text][bt_hr top_spaced=”topSemiSpaced” bottom_spaced=”not-spaced” transparent_border=”noBorder” el_class=”” el_style=””][/bt_hr][/bt_column][/bt_row][bt_row][bt_column width=”1/1″][bt_hr top_spaced=”not-spaced” bottom_spaced=”bottomSemiSpaced” transparent_border=”border” el_class=”” el_style=””][/bt_hr][/bt_column][/bt_row][/bt_section][bt_section][bt_row cell_spacing=”” el_class=”” el_style=””][bt_column width=”1/1″ align=”left” vertical_align=”inherit” border=”no_border” cell_padding=”default” animation=”no_animation” highlight=”no_highlight” background_color=”” transparent=”” inner_background_color=”” background_image=”” el_class=”” el_style=””][bt_tabs][bt_tabs_items headline=”Features”][bt_text]

 Gas Sampling Natural diffusion
• Detection Range—0-100% of LEL
• Preset Alarm Levels a) Low Alarm Level b) High Alarm Level
• Auto Calibrated
• Response Time T90 less than 30Sec.
• Infra Red sensor is used
• PFC Relay NO or NC PFC O/P and It will be Selectable Latching type or
Pulse Type
• Sensor Life : Up to 15 years
• Analog O/P : Selectable 0-5 V & 0-10V output
4-20mA current output
• Operating Voltage Range is 18 to 32VDC
Salient Features:
 Long Operating Life.
• No Routine Calibration Required, hence reducing maintenance cost &
Time.
• Operated in Inert Atmospheres.
• Fast Response.
• Ability to Operate in the Absence of Oxygen or in enriched oxygen.
• Replaceable Sensor Provision.
• Magnetic Key Operations.
• Wide Operating Temperature Range.
• Immune to Catalytic Poisons.
• Failsafe Operation.
• No moving parts , hence No drift.
 High reliability & repeatability.
• ATEX Certified.
 CCOE (PESO) Certified
 BIS—CM/L—3927980 Certified
TS21I-IR Detector detects following gases:
Hydrocarbon, LPG, PNG, CNG, Carbon Dioxide, Methane, Propane, Propylene, Butane, Pentane, Hexane, Ethylene, Ethylene Oxide, Ethane, Ethanol, Hydro-carbon+CO2

[/bt_text][/bt_tabs_items][bt_tabs_items headline=”Technical Specification”][bt_text]

Gas Sampling Infrared absorp-tion Detection Level 0—100% LEL
Gas Sensor Type Infrared Output Four Digit 7-Sigment
Display
PFC Relay,(NC & NO)
Power sup-ply 18VDC to 32VDC Optional RS-485, Valve out-put. 4-20mA Output 0-5V & 0-10V Output
Power Con-sumption 2W / 5WMax. Working Temperature -20°C to 80°C