Adddressable Gas Detection System – AGDS-96

[bt_section layout=”boxed” top_spaced=”topSemiSpaced” bottom_spaced=”bottomSemiSpaced” skin=”inherit” full_screen=”no” vertical_align=”inherit” divider=”no” back_image=”” back_color=”” back_overlay=”” back_video=”” video_settings=”” back_video_mp4=”” back_video_ogg=”” back_video_webm=”” parallax=”” parallax_offset=”” animation=”” animation_back=”” animation_impress=”” el_id=”” el_class=”” el_style=””][bt_row][bt_column width=”1/3″ align=”left” vertical_align=”inherit” border=”no_border” cell_padding=”default” animation=”animate animate-fadein” text_indent=”no_text_indent” highlight=”no_highlight” background_color=”” transparent=”” inner_background_color=”” background_image=”” el_class=”” el_style=””][bt_image image=”3371″ caption_text=”” caption_title=”” show_titles=”no” size=”full” shape=”square” url=”” target=”_self” el_class=”” el_style=”” hover_type=”btDefaultHoverType”][/bt_image][bt_hr top_spaced=”topSemiSpaced” bottom_spaced=”not-spaced” transparent_border=”noBorder” el_class=”” el_style=””][/bt_hr][/bt_column][bt_column width=”2/3″ align=”left” vertical_align=”inherit” border=”no_border” cell_padding=”default” animation=”animate animate-fadein” highlight=”no_highlight” background_color=”” transparent=”” inner_background_color=”” background_image=”” el_class=”” el_style=””][bt_header superheadline=”” headline=”Description” headline_size=”small” dash=”bottom” subheadline=”” el_class=”” el_style=”” headline_style=”regular”][/bt_header][bt_hr top_spaced=”not-spaced” bottom_spaced=”bottomSmallSpaced” transparent_border=”noBorder” el_class=”” el_style=””][/bt_hr][bt_text]

Addressable Gas Detection System is specifically designed for gas leakage monitoring applications in industries such as gas plants, storage facilities and terminals, refineries, natural gas processing, gas pipelines, pumps and com-pressor stations where the gas may leak.
The AGDS-96, Gas Detection System consists of one control panel and up to
96 Addressable gas detectors and signal output devices. This networked sys-tem creates a plant-wide, distributed safety system. 2 wire bus structure en-ables easy installation.
When the gas leakage reaches or exceeds the set point, the control panel gives audio and visible warning. It can also drive corresponding control output
to switch ON ventilation and switch-off the control valve to avoid accident
in advance.
Panel has Provide Optional Ethernet /GSM/GPRS Connectivity as well as CMS monitoring.
AGDS-96 System has provision for installing battery for providing typical backup time of about 7-8 hours. Other features include connection to GAS
Valve Shut OFF and report to the CMS With Optional CMS Connectivity.

[/bt_text][bt_hr top_spaced=”topSemiSpaced” bottom_spaced=”not-spaced” transparent_border=”noBorder” el_class=”” el_style=””][/bt_hr][/bt_column][/bt_row][bt_row][bt_column width=”1/1″][bt_hr top_spaced=”not-spaced” bottom_spaced=”bottomSemiSpaced” transparent_border=”border” el_class=”” el_style=””][/bt_hr][/bt_column][/bt_row][/bt_section][bt_section][bt_row cell_spacing=”” el_class=”” el_style=””][bt_column width=”1/1″ align=”left” vertical_align=”inherit” border=”no_border” cell_padding=”default” animation=”no_animation” highlight=”no_highlight” background_color=”” transparent=”” inner_background_color=”” background_image=”” el_class=”” el_style=””][bt_tabs][bt_tabs_items headline=”Features & Specifications”][bt_text]

• 96 Zone Addressable Inputs (RS-495).
• 16*2 Back light LCD display
• 2 Wire Bus Structure
• Fast response.
• Capacitive touch pad with 20 keys.
• Up to 8 hours battery Backup (without detector).
• Siren output is available(110db).
• Auxiliary relay output is provide for interface other system.
• Optional communication interfaces.
• 100 Event Logs.

[/bt_text][/bt_tabs_items][bt_tabs_items headline=”Technical Specification”][bt_text]

Power Supply 170-230VAC,50/60Hz Output 16*2 LCD Display
Siren Output (Two Siren)
PFC Relay & LED Output
Audio Buzzer
Battery
Backup
Up to 7-8Hr
(12VDC/4.5Ah)
Optional
O/p
RS-485, RS-232, GSM auto Dialer
Input 96 Zone Addressable
GAS Detection Inputs
(RS-485)
Humidity 5 to 95% Rh
Size (450x250x100) mm
(LxWxH)
Working Temperature 0°C to 50°C

[/bt_text][/bt_tabs_items][bt_tabs_items headline=”Catalog”][bt_text]

AAx3 Battery
[/bt_text][/bt_tabs_items][bt_tabs_items headline=”Certification”][bt_text]

Green-Power ON Condition
RED-Alarm Condi-tion
[/bt_text][/bt_tabs_items][/bt_tabs][/bt_column][/bt_row][/bt_section]